Inspect the thermostat seal and the thermostat cover
gasket surface for cracks, corrosion, or damage. Replace
the thermostat cover if necessary. The thermostat seal
can not be reused. The seal must be replaced if it is
removed from the cover.
Inspect the thermostat for damage.
Suspend the thermostat and a 100° C [212° F] ther-
mometer in a container of water. Do not allow the ther-
mostat or the thermometer to touch the sides of the con-
tainer. Heat the water.
NOTE: Record the temperatures at which the thermostat
begins to open and when it is fully open. Allow several
minutes for the thermostat to react to a stabilized water
temperature.
NOTE: The nominal operating temperature is stamped on
the thermostat.
The thermostat must begin to open within C [2° F] of
nominal temperature.
The thermostat must be fully open to at least 9.5 mm
[0.375-inch] within 12° C [22° F] above nominal temper-
ature.
Replace the thermostat if it does not operate as described.
Cooling System Thermostat Housing - Cleaning and Inspection (08-05)
N14 Page 8-21