NOTE: If an external pressure pump is not available, prime
the lubricating system as follows:
Use the dipstick to measure the lubricating oil level.
Fill the oil pan to the ‘‘high’’ level mark on the dipstick.
Disconnect the turbocharger lubricating oil supply line.
Pour 50 to 60 cc [2.0 to 3.0 fl oz] of clean 15W-40 oil in
the turbocharger oil supply line fitting.
Install the turbocharger oil supply line.
Torque Value: 30 N•m [22 ft-lb]
Use clean 15W-40 oil to fill the lubricating oil filter.
Tighten the filter until the gasket contacts the filter head
surface.
Tighten the filter an additional three-fourths to one (3/4 to
1) turn.
Priming the Lubricating Oil and Fuel Systems (14-02) Engine Testing