Connect the dynamometer test OEM wiring harness start-
ing motor solenoid lead (yellow) to the starting motor
solenoid. Connect the ground lead (black) to the starting
motor or battery negative or ground side. Connect the
+12 volt DC power lead (red) to either the starting motor
or battery positive (+12 volt DC) side.
To control throttle input and engine speed, connect the
auto/manual throttle control, Service Tool Part No.
3823828, to the throttle control leads at the keyswitch
panel on the dynamometer test OEM wiring harness.
Place the ‘‘Auto-Manual’’ switch in the ‘‘Manual’’ posi-
tion to enable use of the ‘‘Min-Max RPM Adjust’’ control.
Connect the keyswitch panel datalink cable to the
Compulink™.
Depress the ‘‘POWER ON’’ button on the Compulink™.
If the ‘‘Progressive Shift Feature’’ is turned ‘‘ON’’, it
must be turned ‘‘OFF’’ during the engine test to allow the
engine to accelerate through its RPM range.
Select the ‘‘Adjustments’’ option from the main menu
screen by depressing the number ‘‘2’’ on the Compulink™
keypad.
Engine Dynamometer - Install Engine (14-01) Engine Testing
N14Page 14-16
Perfect..